Check, double check, triple check.
Repeated units can morph over time, and even within a building plan, especially if the building has a subtle shape change (i.e. parallelogram) or there are outside corner and inside corner units.
Check for dimensional regularity of critical spaces (front entry, door clearances, kitchens, and bathrooms) to find anomolies in the layouts.
Georgia Commons units, especially types 1A & 1B, represent these unique conditions within "regularized" layouts.
Showing posts with label Georgia Commons. Show all posts
Showing posts with label Georgia Commons. Show all posts
Tuesday, May 18, 2010
Monday, May 17, 2010
Sunday, May 16, 2010
Stairwell door fire safety/security
IBC requires positive latching at all doors, and passage between stairwell and floor served.
Buildings that require stairwell security require electric strikes or trim to achieve this.
Electric strikes will only comply with both if Hi-Tower strike is used. Otherwise utilize electrified cylinder trim (with electric hinge). Or other options, like these.
More research here.
Code citations:
IBC 2006 1008.1.8.7 & 403.12
NFPA 1014 7.2.1.5.7 sections 1-10
IIC ratings
Impact insulation class (IIC) ratings are required to be 50 (45 if field tested).
These are not enforced by local jurisdictions, at least not lately, but they may become popular among the litigious crowd.
Hard surfaces: Use underlayment under tile/hardwood.
Bare concrete (stained) while hip is a tough surface to clad to meet IIC.
Soft vinyl and carpeting approach 50 IIC plus.
Links:
How resilient channels absorb sound waves. Resilient channels lose their effectiveness when they are "shorted out".
IIC definition. Shows axon sketches of different material configurations.
Sound deadening materials. And techniques, too.